Menu
Your Cart
  • Previous

    Breathalyzer Alcovisor Mars BT with printer
  • Next

    Breathalyzer Alcovisor Mark V+ with printer

Breathalyzer Alcovisor Jupiter with built-in printer

Breathalyzer Alcovisor Jupiter with built-in printer
Breathalyzer Alcovisor Jupiter with built-in printer
Breathalyzer Alcovisor Jupiter with built-in printer
Breathalyzer Alcovisor Jupiter with built-in printer
Breathalyzer Alcovisor Jupiter with built-in printer
Breathalyzer Alcovisor Jupiter with built-in printer
Breathalyzer Alcovisor Jupiter with built-in printer
Breathalyzer Alcovisor Jupiter with built-in printer
Breathalyzer Alcovisor Jupiter with built-in printer
Breathalyzer Alcovisor Jupiter with built-in printer
Breathalyzer Alcovisor Jupiter with built-in printer
Breathalyzer Alcovisor Jupiter with built-in printer
Breathalyzer Alcovisor Jupiter with built-in printer
Breathalyzer Alcovisor Jupiter with built-in printer
Breathalyzer Alcovisor Jupiter with built-in printer
Breathalyzer Alcovisor Jupiter with built-in printer
Breathalyzer Alcovisor Jupiter with built-in printer
Breathalyzer Alcovisor Jupiter with built-in printer
Breathalyzer Alcovisor Jupiter with built-in printer
Breathalyzer Alcovisor Jupiter with built-in printer
Breathalyzer Alcovisor Jupiter with built-in printer
4,650.00 zł
Ex Tax: 3,780.49 zł
  • Stock: In Stock
  • Model: AL-C4-JUP-PR
  • EAN: 6934945200451
  • Weight: 435g
  • Dimensions: 195mm x 79mm x 35mm
I

Alcovisor® Jupiter is one of the most technologically advanced exhaust analyzers with a large TFT touch screen and a built-in thermal printer. Thanks to the use of an electrochemical sensor that reacts only to alcohol molecules, it provides extremely precise and repeatable measurements.

The results are displayed with a resolution of up to thousandths, in user-defined units. The breathalyzer can be operated with a stylus or directly with the fingers, thanks to which the selection of individual functions and data entry is efficient, which significantly reduces the time needed to perform the measurement.

The test can be performed in one of the three measurement modes: short (quick), full and full, in which you can enter, among others, data of the tested person and the person carrying out the test, vehicle number, etc. Additionally, in each of the above-mentioned modes, the user has the option of selecting an automatic or manual method of taking the measurement sample. The manual method is used when the test person makes it impossible to carry out the test, is unable to blow out the required amount of air or is unconscious. A specially designed mouthpiece prevents incorrect application on the handle and prevents the contact of the tested person's mouth with the analyzer housing. The air inlet system protects the sensor against damage by administering an air sample contaminated with saliva, liquid or solid substances.

When checking a larger number of people in a short period of time (e.g. at sports events, discos, prisons, schools), a special funnel cap can be used instead of the traditional mouthpiece. During the inspection, the test person's mouth does not come into contact with the cap, therefore it can be used many times. Thanks to this solution, you can reduce the costs associated with the use of disposable mouthpieces.

The tester's memory can store up to 20,000 measurement results with date, time, data of the subject and operator, and the place where they were performed. This information can be displayed on the tester's screen and printed at any time. Built-in USB port allows you to download data to a PC.

An additional advantage is the ability to define the analyzer settings (including measurement units, exhalation force and time, information on the printout, number of printed copies, etc.) according to the user's requirements.

Alcovisor® Jupiter can be powered by a rechargeable NI-MH battery, a cigarette lighter socket or a mains adapter. It has a low battery indication and an automatic power cut-off function. The backlit screen and the mounting of the mouthpiece socket enable efficient examination at low light intensity, e.g. at night.

APPLICATION
Breathalyzer Jupiter is recommended for intensive sobriety control of employees and drivers. It will also work well in testing sobriety, e.g. participants of sports events, in hospitals, schools, prisons, and military units. A printout of the measurement carried out with the Alcovisor® Jupiter can be used as evidence in court cases *.

ADVANTAGES

  • Platinum electrochemical sensor from a renowned British company
  • Long-term stability of the measuring cell
  • Backlit, 3.2 "TFT touch screen
  • Display resolution up to 3 decimal places
  • High accuracy and repeatability of measurements
  • Possibility to measure with a mouthpiece or a funnel cap
  • Short preparation time for work and between consecutive measurements
  • Automatic saving of results in the device memory up to 20,000 measurement data
  • Possibility to define according to the user's requirements: measurement units, information on the printout, number of printed copies, time and strength of the sample, shutdown time
  • Various power options
  • Automatic power cut-off function
  • USB port for external power connection and connection to a PC
  • Compact structure and durable structure
  • Automatic mouthpiece ejector
  • Built-in thermal printer
  • Low noise level when printing
  • Printout of any measurement result stored in memory
  • Calibration certificate from an accredited laboratory **
  • 2-year warranty

printout of the measurement carried out with an Alcovisor® Jupiter may be used as evidence in court cases. Applies to devices sold complete with a printer and with a valid calibration certificate issued by an accredited laboratory
** option additionally payable

Product information
Sensor type Fuel Cell
Measurement range 0.000 – 6.300 ‰
Measurement units ‰, % BAC, g/100mL, g/L, mg/100ml, mg/L, mg/ml, ug/100mL
* Possibility to change the measuring unit by the service. Factory setting: ‰ permille.
Display resolution 0.001 ‰
Accuracy of indications ± 5%
* For a correctly calibrated device.
Alarm threshold None
Time to prepare for work Less than 2 seconds
* Time to prepare the device for the first measurement.
Sampling time ± 5 seconds
Measurement modes Fast - with a passive sample cup
Normal - with a mouthpiece
Sampling mode Automatic
Manual
Memory 10'000 measurement records
Cooperation with application No
Cooperation with printer Yes
Display 2.4" TFT colour screen display (65,000 colours)
Housing ABS, impact resistant
USB port For connecting an external power supply
Usage Large, medium and small companies, personal use, screening
Additionally included Ni-MH rechargeable battery
Printer paper - 2 pcs.
Mouthpieces - 5 pcs.
Funnel cap
Pouch
Case
Rysik
User manual
Warranty card
Printer information
Printed data Measurement result, other data (e.g. test number, device number, last calibration date, measurement time, date etc.)
Printing method Thermal
Thermal paper Roll width 57 mm, max. diameter 35 mm
Printing speed Approx. 10 seconds / copy
Number of copies per roll Approx. 50
Working conditions Temperature: -5 ~ 45°C
Humidity: up to 85% RH
Storage conditions Temperature: -15 ~ 65°C – without batteries
Humidity: up to 85% RH
Power source Ni-MH rechargeable battery with a capacity of 1800mAh
Weight and external dimensions 155 g (without batteries & paper)
120 x 80 x 35 mm
Housing ABS, impact resistant
Power
Power source 7.4V 1800 mAh rechargeable NI-MH battery
Possibility of power supply from 230V AC / 12V DC mains adapter
Possibility of power supply from the car lighter socket
USB port
Energy saving Automatic power off after 1, 3, 5 or 10 min - user defined
Working and storage conditions
Working conditions Temperature: -10 ~ 40°C
Humidity: up to 95% RH
Storage conditions Temperature: -20 ~ 70°C – without batteries
Humidity: up to 95% RH
Quality and safety
Certificates and approvals DOT, CE and RoHS
Recommended calibration Every 6 months or 300 measurements (whichever comes first)
Warranty 2 years
Individually packed original mouthpieces for Alcovisor Mercury and Alcovisor Jupiter breathalyzers.It also works well with other models of breathalyzers, such as AlcoDigital P•100, P•200.The design of the mouthpiece can affect the device's ability to accurately determine the alcohol concentration in..
2.69 zł
Ex Tax:2.19 zł
Individually packed original funnel cap for Alcovisor Mercury and Alcovisor Jupiter breathalyzers.It also works well with other models of breathalyzers, such as AlcoDigital P•100, P•200.The non-funnel cap can be used repeatedly, e.g. when checking a larger number of people, thanks to which you can r..
11.50 zł
Ex Tax:9.35 zł
Thermal paper designed for the Alcovisor® Jupiter breathalyzer & the wireless printer for the Alcovisor® Mercury breathalyzer.It is also suitable for AlcoDigital P•100, P•200.Product sold individually...
11.00 zł
Ex Tax:8.94 zł
Rechargeable 1800mAh lithium-ion battery recommended to power the Alcovisor Jupiter breathalyzer and thermal printer WPT-2.Nominal voltage: 7.4VCharge limit voltage: 8.4VCharging temperature: 0 ~ 40°CThe ordered battery may differ from those shown in the picture...
198.00 zł
Ex Tax:160.98 zł

Write a review

Reviews policy.
Please login or register to review
The website uses cookies to provide services in accordance with the Privacy Policy. You can define the conditions for storing or accessing cookies in your browser. You can find out more about cookies in the Cookies tab.