AZ 7702 is a professional, portable carbon monoxide (CO) meter, designed for precise measurements in gas installations, heating systems, and wherever safety and reliable results are crucial.
The device is equipped with a high-quality electrochemical sensor that ensures a fast response time and very good measurement accuracy – up to ±3 ppm at low concentrations. The manual zeroing function allows you to eliminate background influences and precisely locate the source of carbon monoxide emissions. A clear LCD display with backlight and an adjustable audible alarm ensure comfortable and safe work both in technical rooms and in the field.
AZ 7702 meets the requirements of the EN 50543, NF P45-500 and NF X50-010 standards, making it a suitable tool for professional inspections, audits and service work on gas appliances and heating installations.The high quality of the components used allows for additional calibration to be carried out in an accredited laboratory, which increases the reliability of measurements and enables the device to be used in professional applications.
A major advantage of the device is the ability to save up to 99 measurement results and cooperation with an IR printer, which allows for the immediate creation of reports and measurement documentation - especially useful for service technicians, installers and inspectors.
The device It is powered by 4 x 1.5V AA alkaline batteries (included). The battery charge status is monitored in real-time mode on the display.
APPLICATION
Enables quick and precise checking of rooms and installations for the presence of carbon monoxide. Recommended for use by gas equipment installers and service technicians, chimney sweeps, occupational health and safety personnel, installation inspectors and auditors, technical and maintenance services, and others. Suitable for monitoring boilers, furnaces, gas installations, and in residential and commercial spaces.
ADVANTAGES
- Precise electrochemical sensor with high accuracy
- Wide measurement range: 0 ~ 1000 ppm
- High accuracy, up to ±3 ppm at low concentrations
- Fast response time (T90 ≤ 60 s)
- Manual zeroing and 3-point calibration function
- Adjustable audible alarm (default 15 ppm)
- Option to store 99 measurements
- Automatic temperature compensation (ATC)
- LCD display with backlight and built-in clock
- IR output for use with a printer (optional)
- Convenient battery power supply: 4 x 1.5V, AA type (included)
- Long battery life (up to approx. 700 h)
| Product information | |
| Memory | 99 measurements, recording on demand by pressing a button |
| Measurement of CO concentration | |
| Sensor type | Electrochemical |
| Detected gases | Carbon monoxide (CO) |
| Response time | < 1 min* for 90% signal change * Time from first device start-up |
| Modes of operation | Real-time Display of minimum/maximum detected values Option to hold readings (HOLD) Option to save readings (MEM) |
| Time to prepare for work | < 30 sec. |
| Measurement units | ppm |
| Measurement range | 0 ~ 1000 ppm |
| Measurement resolution | 1 ppm |
| Accuracy of measurement | ±3 ppm (< 20 ppm) ±5 ppm (21 ~ 100 ppm) ±10% (101 ~ 500 ppm) ±20% (501 ~ 1000 ppm) |
| Alarm threshold | 15 ppm (factory setting), adjustable in 5 ppm increments |
| Signaling | CO warning alarm audible (80 dB) |
| Sygnalizacja przekroczenia zakresu pomiarowego | E02 The value is under range E03 The value is over range |
| Display | LCD 44 x 26 mm, two-field with the option of backlighting LCD |
| Additional features | IR port - for printing using the IR88998 printer Temperature indicator - value is displayed when the meter is turned on Automatic Temperature Compensation (ATC) function 3-point CO calibration (0//100/400 ppm) |
| Additionally included | 4 x 1.5V DC AA alkaline batteries Plastic case Instruction manual in Polish |
| Temperature measurement | |
| Response time | < 2 min* for 90% signal change * Time from first device start-up |
| Measurement range | -20 ~ 60°C (-5 ~ 140°F) |
| Accuracy of measurement | ±0.6°C @ 5 ~ 40°C (±1.0°C for others) ±1.0°F @ 41 ~ 104°F (±1.8°F for others) |
| Measurement resolution | 0.1°C / °F |
| Power | |
| Power source | 4 x 1.5V DC alkaline batteries, type AA |
| Battery life | ±500 hours (under normal conditions of use) |
| Power consumption | <1.4 mA while backlight is off |
| Energy saving | Auto power off after 20 minutes of inactivity |
| Battery discharge indication | Yes |
| Working and storage conditions | |
| Working conditions | Temperature: 0 ~ 50°C Humidity: 10 ~ 95% RH, non-condensing |
| Storage conditions | Temperature: -20 ~ 60°C - without batteries Humidity: 5 ~ 95% RH, non-condensing |
| Quality and safety | |
| Certificates and approvals | CE Optional calibration certificate (valid for 6 months) |