Menu
Your Cart
  • Previous

    Multifunction meter AZ 89053
  • Next

    Multifunction meter with bluetooth AZ 89321

Multifunction meter DT-859B

Multifunction meter DT-859B
Multifunction meter DT-859B
Multifunction meter DT-859B
Multifunction meter DT-859B
Multifunction meter DT-859B
Multifunction meter DT-859B
Multifunction meter DT-859B
Multifunction meter DT-859B
Out of Stock
Multifunction meter DT-859B
Multifunction meter DT-859B
Multifunction meter DT-859B
Multifunction meter DT-859B
Multifunction meter DT-859B
Multifunction meter DT-859B
Multifunction meter DT-859B
Multifunction meter DT-859B
Multifunction meter DT-859B
598.00 zł
Ex Tax: 486.18 zł
  • Stock: Out of Stock
  • Model: DT-859B
  • EAN: 5907222598764
  • Weight: 365g
  • Dimensions: 65mm x 45mm x 248mm
I

DT-859B is a multifunction meter that combinesfunctionality of up to five advanced measuring devices.

It is designed to measure environmental parameters suchsuch as: lighting intensity, air humidity, temperature,the sound intensity as well as the speed and efficiency of the flow air.

Silicon photocell, vane probe and temperature sensorand humidity are equipped with a connection cable enabling measurement even in hard-to-reach places. Moisture measurement temperature is done with a semi-conductor probe. The K-type probe measures extremely low and high temperatures (-200 ~ 1372°C).

User can choose the measurement units anddisplay resolution. Device can operate in the measurement mode of current values ​​and reading the minimum and maximum values and medium (MIN / MAX / AVG function). DATA HOLD function allows you to keep the current indications on the display.

DT-859B is powered by a 9V alkaline battery. It has signaling battery discharge and auto-off function that automatically turns off device after 20 minutes of inactivity (with an option to deactivate)

APPLICATION
DT-859B is perfect for people who are looking for a high-quality device, allowing the measurement of many parameters. It will work both for professional use and for laboratory purposes and home use.

ADVANTAGES

  • High functionality of up to 5 advanced devices in 1
  • Multifunctional 3 ½ digit backlit LCD display
  • High measurement accuracy for all parameters
  • Wide measuring range for all measured values
  • Specialized K-type thermocouple for extreme temperatures measurement
  • A and C correction filters for sound measurement
  • Simple operation
  • MIN, MAX, AVG function - minimum, maximum, average values measurement
  • DATA HOLD function - holding the current indication ondisplay
  • Convenient battery power supply with low battery indication
  • Auto power off function (with deactivation)
Product information
Display 3 ½ digit LCD, acklit
Additional features DATA HOLD - hold the current indication on the display
MIN, MAX, AVG - minimum, maximum, average value of the measurement
Additionally included User manual
K-type temperature probe
Semiconductor temperature and humidity probe
Vane probe
Photometric probe
Case
Measurement of air speed
Measurement range 0.40 ~ 30.00 m/s
80 ~ 5900 ft/min
1.4 ~ 108.0 km/h
0.9 ~ 67.0 MPH
0.8 ~ 58.0 Knots
Accuracy of measurement ±3% ±0.20 m/s
±3% ±40 ft/min
±3% ±0.8 km/h
±3% ±0.4 MPH
±3% ±0.4 knots
* Accuracy may decrease with time flow. It is recommended to perform regular service inspections.
Measurement resolution 0.01 m/s
0.01 m/s
0.1 km/h
0.1 MPH
0.1 knots
Measurement of air flow efficiency
Measurement range 0 ~ 999900 CFM / CMM
Accuracy of measurement Accuracy is a function of speed and field
* Accuracy may decrease with time flow. It is recommended to perform regular service inspections.
Measurement resolution 0.001 ~ 100 CFM / CMM
Measurement of light intensity
Head type Silicon photocell with filter
Measurement range 20, 200, 2000, 20000 (2000 x 10 Lux)
Accuracy of measurement ±5.0% +10d
* Accuracy may decrease with time flow. It is recommended to perform regular service inspections.
Measurement resolution 0.01, 0.1, 1, 10 Lux
Sound volume measurement
Measurement range 30 ~ 130dB
Accuracy of measurement ± 3.5dB at 94dB 1kHz sound level, sine wave
* Accuracy may decrease with time flow. It is recommended to perform regular service inspections.
Measurement resolution 0.1
Correction filters A i C
Humidity measurement
Measurement range 0 ~ 100% RH
Accuracy of measurement ±3.5% RH
* Accuracy may decrease with time flow. It is recommended to perform regular service inspections.
Measurement resolution 0.1
Temperature measurement
Measurement range -30 ~ 60°C for a semiconductor probe
-200 ~ 1372°C for K type probe (determined by the type of used probe)
Accuracy of measurement
» semiconductor probe
±1°C; (10 ~ 30°C)
±2°C: (for other ranges)
* Accuracy may decrease with time flow. It is recommended to perform regular service inspections.
Accuracy of measurement
» K type probe
±1.5% ±1°C; (-99.9 ~ 99.9°C)
±1.5% ±2°C; (for other ranges)
* Accuracy may decrease with time flow. It is recommended to perform regular service inspections.
Measurement resolution
» semiconductor probe
0.1 (10 ~ 30°C) 0.1, 1 (for other ranges)
Measurement resolution
» K type probe
0.1, 1 (for all ranges)
Power
Power source 1 x 9V alkaline battery
Energy saving Auto power off after 20 minutes (can be disabled)
Battery discharge indication Yes
Quality and safety
Certificates and approvals CE mark
Alkaline battery 9V, type 6LR61 - 1 pc.The ordered batteries may differ from those shown in the picture...
10.00 zł
Ex Tax:8.13 zł

Write a review

Reviews policy.
Please login or register to review
The website uses cookies to provide services in accordance with the Privacy Policy. You can define the conditions for storing or accessing cookies in your browser. You can find out more about cookies in the Cookies tab.