Menu
Your Cart
  • Previous

    Paint thickness gauge Blue Technology MGR-10-S-FE
  • Next

    pH monitor AZ 8605

Extremely low temperature data logger with probe AZ 88264

Extremely low temperature data logger with probe AZ 88264
Extremely low temperature data logger with probe AZ 88264
Extremely low temperature data logger with probe AZ 88264
Extremely low temperature data logger with probe AZ 88264
Extremely low temperature data logger with probe AZ 88264
Out of Stock
Extremely low temperature data logger with probe AZ 88264
Extremely low temperature data logger with probe AZ 88264
Extremely low temperature data logger with probe AZ 88264
Extremely low temperature data logger with probe AZ 88264
Extremely low temperature data logger with probe AZ 88264
Extremely low temperature data logger with probe AZ 88264
879.00 zł
Ex Tax: 714.63 zł
  • Stock: Out of Stock
  • Model: AZI-88264
  • Weight: 50g
  • Dimensions: 45mm x 17mm x 110mm
I

AZ 88264 is a data logger for extremely low temperatures with a USB output for data download and an advanced external probe.

The probe has PT1000 temperature sensor and has been specially designed to measure extremely low temperatures. It enables temperature registration in the range of -100 ~ 120°C. The whole thing is mounted on a silicone cable with a length of approx. 200 cm. The results are stored in the memory with a total capacity of 48,000 measurement points.

Programming the recorder (e.g. changing the interface language, setting the sampling frequency, alarm thresholds, delaying the recorder activation, units for temperature, etc.) and reading the results is done using a computer without the need to install additional software. After connecting the recorder to a computer, a measurement report is automatically generated in the form of a PDF file, which contains the compilation of measurement data. Thanks to this, the user has the opportunity to quickly assess the conditions in which the measurements took place.

AZ 88264 is powered by 2 x 3V batteries, type CR2032. The batteries last for about 3 months of uninterrupted operation of the device. Each recorder has a unique serial number that enables unambiguous identification, and also has the option of entering a username and a password.

APPLICATION
AZ 88264 is suitable for monitoring and controlling temperature in industrial refrigerators and cold rooms, refrigeration machines, containers for storing and transporting food and drugs, as well as in warehouses, laboratories, cellars, etc.

ADVANTAGES

  • Very wide measuring range (-100 ~ 120°C)
  • External probe on a 200 cm long silicone cable
  • Built-in PT1000 sensor for detecting extremely low temperatures
  • Operation of the recorder without the need to install additional software
  • Memory of total capacity of 48,000 measurement points
  • Sampling time set in the range: 30 sec. ~ 120min.
  • Possibility to set alarm thresholds and the delay time of the recorder activation
  • Signaling of exceeding the set alarm thresholds
  • LED diodes - green and red informing about the operating mode
  • MARK button - marker for recording important events
  • Automatic generation of data reports in PDF format
  • You can replace the battery yourself
  • Factory calibrated device
  • Compact dimensions, easy operation
Product information
Product type Multi-use
Memory 48'000 samples for temperature (24'000 int. device & 24'000 etx. probe)
Alarm type Single event / collective alarm / no alarm
Alarm thresholds Programmable at range: -30 ~ 70°C
Alarm delay 0, 5, 30, 45, 60, 90, 120 minutes
Activation delay 0, 5, 30, 45, 60, 90, 120 minutes
Sampling frequency 30 sec; 5, 10, 30, 60, 90, 120 min.
Buttons Start / Stop
MARK - marker of important events
LED lights REC, OK, LOW/HI alarm
Sockets, connectors, ports USB 2.0 - for downloading data to a computer
Additional features Probe with PT1000 sensor for detecting extremely low temperatures
Option to set a password to protect against opening
Additionally included 2 x 3V battery, type CR2032
External probe with PT1000 sensor
User manual
Temperature measurement
Measurement range Datalogger: -30 ~ 70°C (-22 ~ 158°F)
Ext. probe: -100 ~ 120°C (-148 ~ 248°F)
Accuracy of measurement Datalogger: ±0.5°C
Ext. probe*: ±0.5°C
* Logger placed at temperature: 10 ~ 40°C.
** Accuracy may decrease with use. It is recommended to calibrate the device regularly.
Measurement resolution 0.1
Units of measurement °C / °F
Power
Power source 2 x 3V battery, type CR2032 (can be replaced)
Battery life ±3 months from the moment of activation*
* This is the maximum battery life. Battery life can be influenced by e.g. high activation frequency alarm, exposure of the device to temperatures outside the operating range specified in the specification, etc.
Battery discharge indication Yes
Working and storage conditions
Working conditions Temperature: -70 ~ 80°C (device); -100 ~ 120°C (ext. probe)
Humidity: up to 90% RH, non-condensing
* Room temperature ±25°C - when uploading data to a PC
Storage conditions Temperature: -40 ~ 85°C
Humidity: up to 90% RH non-condensing
Quality and safety
Certificates and approvals CE mark