Air parameters meter with relay AZ 7722

Air parameters meter with relay AZ 7722
Air parameters meter with relay AZ 7722
Air parameters meter with relay AZ 7722
Air parameters meter with relay AZ 7722
Air parameters meter with relay AZ 7722
Air parameters meter with relay AZ 7722
Air parameters meter with relay AZ 7722
989.00 zł
Ex Tax: 804.07 zł
  • Stock: In Stock
  • Model: AZI-7722
  • EAN: 5907222598276
  • Weight: 190g
  • Dimensions: 85mm x 60mm x 130mm

Available Options

I

AZ 7722 is a meter designed to monitor indoor air quality.

Adapted for continuous operation using the control function, through the relay output, external devices (e.g. fans, solenoid valves, etc.) or for routine instantaneous measurements.

It allows the simultaneous measurement of carbon dioxide, temperature and humidity. It has a built-in NDIR sensor that allows for precise measurement of CO2 levels in real time and a high-class Rotronic sensor for measuring humidity. Results are presented on a three-field LCD display.

User can set the CO2 alarm threshold after exceeding which the optical and acoustic signaling will be activated, change the temperature reading units (ºC / ºF) and select the values ​​displayed on the LCD panel. Device can work in the mode of measuring current values, minimum / maximum values ​​(MIN and MAX functions) and average values ​​for 8h and 15min time intervals (TWA and STEL functions).

RS232 port enables the connection with a PC in order to save the current indications after prior software installation. Meter has the function of automatic calibration of the CO2 sensor and a two-point calibration of the humidity sensor.

AZ 7722 is powered by a DC 12V 0.5A adapter.

APPLICATION
Meter can be used as the CO2 checker for the air quality index in all workspace, office, hospital, school, station or home. It can be calibrated easily in the fresh air and its back light function could let user operate in the dark area. AZ 7752 is your best choice as the indoor air quality (IAQ) testers.

ADVANTAGES

  • Illuminated, three-field liquid crystal display
  • Stable and accurate NDIR sensor
  • High sensitivity, selectivity and durability
  • Simultaneous measurement of CO2, temperature and humidity
  • Determination of the melting and evaporation point of WET BULB
  • DEW POINT dew point temperature measurement
  • Useful functions: MAX / MIN, TWA and STEL
  • Signaling of exceeding the alarm thresholds
  • Contact output for controlling e.g. fans, contactors, solenoid valves
  • Auto-calibration function for CO2
  • Possibility of cooperation with a PC
Product information
Warm-up time < 30 seconds*
* Time since the device was first powered on
Display LCD 50 x 65 mm; three-pole
Additional features MIN, MAX - measurement mode of the value: minimum, maximum
WET BULB - display of the evaporating temperature at the current air humidity (wet bulb temperature)
DEW POINT - dew point temperature display
TWA and STEL - measurement of average values for 8h and 15 min time intervals.
Sockets, connectors, ports 12V DC socket - for connecting the AC adapter
RS232 port for connection with a PC
Relay output - for connecting external devices (e.g. fans, solenoid valves, etc.)
Relay output 1A 30V DC / 0.5A 125V AC
Additionally included AC adapter 12V DC 0.5A
User manual
Humidity measurement
Sensor type High-sensitivity capacitive sensor - Rotronic
Response time < 10 minutes for 90% step change** Time since the device was first powered on
Measurement range 0.1 ~ 99.9% RH
Accuracy of measurement ±3% for 10 ~ 90% RH at 25°C
±5% for other ranges
* Accuracy may decrease with use. It is recommended to calibrate the device regularly.
Measurement resolution 0.1
Temperature measurement
Response time < 2 minutes for 90% step change** Time since the device was first powered on
Measurement range -10 ~ 60°C (14 ~ 140°F)
Accuracy of measurement ±0.6°C / ±0.9°F
* Accuracy may decrease with use. It is recommended to calibrate the device regularly.
Measurement resolution 0.1
Measurement of CO2 concentration
Sensor type NDIR (nondispersive infrared sensor)
Response time < 30 seconds for 90% step change** Time since the device was first powered on
Measurement range 0 ~ 2000 ppm
2001 ~ 9999 ppm (out of range information)
Accuracy of measurement 30 ppm ±5% of the reading value (for the range 0 ~ 2000 ppm)
* Accuracy may decrease with use. It is recommended to calibrate the device regularly.
Measurement resolution 1 ppm
Sampling frequency 1 time per second
Alarm signaling Modulated sound signal ~80dB
Flashing red LED
WET BULB measurement
Measurement range -5 ~ 59.9℃
Measurement resolution 0.1
DEW POINT measurement
Measurement range -20 ~ 59.9℃
Measurement resolution 0.1
Power
Power source AC adapter 100-240VAC, 50/60HZ / 12V DC 0.5A
Working and storage conditions
Working conditions Temperature: 0 ~ 50°C
Humidity: 10 ~ 95% RH, non-condensing
Storage conditions Temperature: -20 ~ 50°C
Humidity: up to 90% RH non-condensing
Quality and safety
Certificates and approvals CE mark