AZ 7788 is a meter designed to monitor indoor air quality. It allows the simultaneous measurement of carbon dioxide, temperature and humidity.

It has a built-in NDIR sensor that allows for precise measurement of CO2 levels in real time and a high-class Rotronic sensor for measuring humidity. Results are presented on a large LCD display.

Device can work in the mode of measuring current values, minimum / maximum values ​​(MIN / MAX functions). User can set the CO2 alarm threshold after exceeding which the sound signaling will be activated and changing the temperature reading units (ºC or ºF).

Adapted for continuous operation using the control function, through the contact output, external devices (e.g. fans, solenoid valves, etc.) or for routine instantaneous measurements. It has the function of automatic calibration of the CO2 sensor and a two-point calibration of the humidity sensor.

AZ 7788 is powered by a DC 5V 0.5A adapter.

APPLICATION
Meter can be used as the CO2 checker for the air quality index in all workspace, office, hospital, school, station or home. It can be calibrated easily in the fresh air and its back light function could let user operate in the dark area. AZ 7798 is your best choice as the indoor air quality (IAQ) testers.

ADVANTAGES

  • Large, liquid crystal display
  • Stable and accurate NDIR sensor
  • Simultaneous measurement of CO2, temperature and humidity
  • High sensitivity, selectivity and durability
  • Indoor air quality indicator: Good, Normal, Poor
  • Signaling of exceeding the alarm thresholds
  • MAX / MIN function - measurement of minimum and maximum values
  • Auto-calibration function for CO2
  • Indication of the current date and time on the display
  • Contact output for controlling e.g. fans, contactors, solenoid valves
  • Ergonomic and aesthetic housing
Product information
Warm-up time < 30 seconds*
* Time since the device was first powered on
Display LCD 60 x 82 mm
Additional features MIN, MAX - measurement mode of the value: minimum, maximum
Sockets, connectors, ports 5V DC socket - for connecting the AC adapter
Relay output - for connecting external devices (e.g. fans, solenoid valves, etc.)
Relay output 1A 30V DC / 0.5A 125V AC
Additionally included AC adapter 5V DC 0.5A
User manual
Humidity measurement
Sensor type High-sensitivity capacitive sensor - Rotronic
Response time < 10 minutes for 90% step change** Time since the device was first powered on
Measurement range 0.1 ~ 99.9% RH
Accuracy of measurement ±3% for 10 ~ 90% RH at 25°C
±5% for other ranges
* Accuracy may decrease with use. It is recommended to calibrate the device regularly.
Measurement resolution 0.1
Temperature measurement
Response time < 2 minutes for 90% step change** Time since the device was first powered on
Measurement range -10 ~ 60°C (14 ~ 140°F)
Accuracy of measurement ±0.6°C / ±0.9°F
* Accuracy may decrease with use. It is recommended to calibrate the device regularly.
Measurement resolution 0.1
Measurement of CO2 concentration
Sensor type NDIR (nondispersive infrared sensor)
Response time < 2 minutes for 90% step change** Time since the device was first powered on
Measurement range 0 ~ 2000 ppm
2001 ~ 9999 ppm (out of range information)
Accuracy of measurement 50 ppm ±5% of the reading value (for the range 0 ~ 2000 ppm)
* Accuracy may decrease with use. It is recommended to calibrate the device regularly.
Measurement resolution 1 ppm
Sampling frequency 1 time per second
Alarm signaling Modulated sound signal ~80dB
Air quality index: *
  • Good <700 ppm
  • Normal 700 ~ 1000 ppm
  • Poor >1000 ppm
* Thresholds can be changed by the user.
Power
Power source AC adapter 100-240VAC, 50/60HZ / 5V DC 0.5A
Working and storage conditions
Working conditions Temperature: -10 ~ 50°C
Humidity: 5 ~ 80% RH, non-condensing
Storage conditions Temperature: -20 ~ 60°C
Humidity: 5 ~ 90% RH non-condensing
Quality and safety
Certificates and approvals CE mark