Menu
Your Cart

Combined flame & cigarette smoke detector CSA-FGV24

Combined flame & cigarette smoke detector CSA-FGV24
Combined flame & cigarette smoke detector CSA-FGV24
Combined flame & cigarette smoke detector CSA-FGV24
Delivery over a month
Combined flame & cigarette smoke detector CSA-FGV24
Combined flame & cigarette smoke detector CSA-FGV24
Combined flame & cigarette smoke detector CSA-FGV24
Combined flame & cigarette smoke detector CSA-FGV24
2,448.00 zł
Ex Tax: 1,990.24 zł
  • Stock: Delivery over a month
  • Model: RAD-CSA-FGV24
  • EAN: 5904507904081
  • Weight: 500g
  • Dimensions: 120mm x 40mm x 180mm

Available Options

I

CSA-FGV24 dual cigarette smoke and flame detector is a version of the popular CSA-FGV model designed for mains operation. It can only be connected to an external power supply with a DC voltage in the range of 9-24V (9, 12, 18, 24V).

If smoke and / or flame are detected, a programmed file with voice recording in any language is played. The user can program up to 100 messages and select them individually or play them sequentially, where each message in the list is played back after successive detector activations. Intervals between messages can be adjusted with the remote programmer, so that the message will be played back at the right time. Programming and operation of the detector is carried out using the CSA-IR2 wireless remote control (not included in the kit and must be purchased separately).

Housing is made of glass fiber reinforced plastic (GRP plastic). When installing the detector in places where it may be exposed to mechanical damage, destruction or theft, it is recommended to protect the device with a metal protective basket, model CSA-Evolution.

CSA-FGV24 can operate as a standalone unit or be part of the Cig-Arrête® SD Evolution anti-smoking system. Device can be connected, among others smoke and fire detectors, optical-acoustic signaling devices, control panel etc.

APPLICATION
Offices, schools, hospitals, public buildings (courts, offices, banks, etc.), industrial, commercial and sports facilities, drug addiction centers, restaurants, rooms where meals are prepared, pubs, casinos, night clubs, airports and seaports , transportation terminals and all other non-smoking areas.

ADVANTAGES

  • Dual sensor for precise and quick detection of tobacco smoke and fire
  • Coverage of 27m3 (3 x 3 x 3m) - for smoke
  • Detects a 25 mm flame within 1 second at a distance of up to 6m (field of view 120°)
  • Five-step sensitivity adjustment with switch-off option
  • Programming and operating the detector with a wireless remote control (not included)
  • Possibility to program up to 100 voice messages in any language
  • Possibility to set the interval between messages so that the message will be played at the right time
  • SmartWave voice playback software to broadcast clear messages in every area of ​​the facility
  • File structure based on Windows, which allows easy copying of files by "dragging" them to the appropriate place and easy programming
  • The ability to set the volume and the number of repetitions of the messages played
  • Powered via 9-24V DC power supply (9, 12, 18, 24V)
  • Simple assembly and operation
  • Ergonomic and aesthetic housing made of GRP material
Product information
Device type Master
Sensor type Cigarette smoke and flames (fire)
Protected area For cigarette smoke: 27m3 (3 x 3 x 3m)
Sensitivity Detects a 25 mm flame within 1 second at a distance of up to 6m (field of view 120°)
Alarm threshold 5 programmable alarm thresholds:
Very high, high, normal, medium, low or off
Activation signaling Voice prompt selected by the user
Programming Programming and operating the detector with a wireless remote control (not included):
Possibility to program up to 100 voice messages in any language
Possibility to set the interval between messages so that the message is played at the right time
Possibility to set the volume and the number of repetitions of the messages played
Connection type Wired
Sockets, connectors, ports Possibility of wired connection with eg. smoke and fire detectors, optical-acoustic signaling devices, control panel
Mounting Ceiling
Housing Glass fiber reinforced plastic (GRP plastic), color white
Additionally included Mounting bracket
User manual
Power
Power source Via external power supply with a DC voltage in the range of 9-24V (9, 12, 18, 24V)
Working and storage conditions
Working conditions Temperature: -10 ~ 50°C
Humidity: up to 95% non-condensing
Quality and safety
Certificates and approvals CE mark
CSA-IR2 is a wireless remote control for programming and operating Cig-Arrête or SpeechPOD products.When required, remote control can change the type, volume and number of repetitions of the voice message being played, set thresholds, sensitivity of flame and smoke sensors and set the appropriate ti..
155.00 zł